6
BURNER RAPID SEMI-RAPID AUXILIARY
(large) (medium) (small)
POSITION MAX MIN MAX MIN MAX MIN MAX MIN
NOMINAL THERMAL
POWER kW 2.8 0.65 2.0 0.45 1.0 0.33 4.0 1.2
NOMINAL FLOW
RATE m
3
/h 0.266 0.062 0.190 0.043 0.095 0.028 0.381 0.114
NOZZLE REFERENCE 113 Adjust. 96 Adjust. 70 Adjust. 146 Adjust.
NOMINAL THERMAL
POWER kW 2.8 0.65 2.0 0.45 1.0 0.33 4.0 1.2
NOMINAL FLOW
RATE g/h 202 47 144 32 72 24 288 86
NOZZLE REFERENCE 86 40 71 32 50 28 98 56
OVERALL DIMENSIONS
Width: 680 mm.
Depth: 510 mm.
CUT OUT DIMENSIONS
Width: 560 mm.
Depth: 480 mm.
SUPPLY CONNECTIONS
Gas:
RC 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
230 V~50 Hz supply, 3 core flexible cable with non
rewireable plug fitted with a 3 amp cartridge fuse.
Rear Left Burner (rapid)
Heat Input 2.8 kW Natural Gas
(10239 BTU/HR)
2.8 kW L.P.G.
(9556 BTU/HR)
Front Left Burner (auxiliary)
Heat Input 1.0 kW (3413 BTU/HR)
Rear Right Burner (semi rapid)
Heat Input 2.0 kW (6824 BTU/HR)
Front Right Burner (semi rapid)
Heat Input 2.0 kW (6824 BTU/HR)
Central Burner (triple crown)
Heat Input 4.0 kW (13652 BTU/HR)
Burner Dia. Tap By-pass
1/100 mm
Auxiliary 28
Semi-rapid 32
Rapid 40
Triple Crown 56
Aeration adjustment none
NATURAL GAS
20 mbar
TYPE OF
GAS
CHARACTERISTICS
LPG GAS
28-30/37 mbar
1/100 mm
1/100 mm
VALUE = 49.92 MJ/Kg
VALUE = 37.78 MJ/m
3
Ws - 50.7 MJ/ m
3
Instructions for the Installer
Engineers technical data
APPLIANCE CLASS : 3
APPLIANCE CATEGORY: II2H3+
APPLIANCE GAS SUPPLY: Natural gas (2H) G20 / 20
mbar
TRIPLE CROWN
This appliance complies with the following
E.E.C. Directives:
* 73/23 - 90/683
(Low VoltageDirective);
* 93/68 (General Directives);
* 89/336 (Electromagnetical
Compatibility Directive);
* 90/396 (Gas Appliances),
and subsequent modifications
Kommentare zu diesen Handbüchern